1.Are you factory?
Yes, we are factory, all customers are more than welcome to visit our factory .
2.What are the available product certifications?
We have certifications such as: ATEX, CE, CNEX. IS014001, OHSAS18001,SIRA, DCI. Etc
3.What are the available heater fange type, sizes and materials?
WNH industrial electric heater, flange size between 6"(150mm)~50"(1400mm)
Flange standard: ANSI B16.5, ANSI B16.47, DIN, JIS (Also accept customer requirements)
Flange material: Carbon steel, Stainless steel, Nickel-chromium alloy, or other required material
4.What type of temperature sensors are provided with the heater?
Each heater is provided with temperature sensors at the following locations:
1) on the heater element sheath to measure maximum sheath operating temperatures,
2) on the heater fange face to measure maximum exposed surface temperatures, and
3) An Exit temperature measurement is placed on the outlet pipe to measure the temperature of the medium at the outlet. The temperature sensor is a thermocouple or PT100 thermal resistance, according to customer requirements.
5.What other controls are needed for safe operation of the process heater?
The heater needs a safety device to ensure the safe operation of the heater.
Each heater is equipped with an internal temperature sensor, and the output signal must be connected to the control system to realize the over-temperature alarm of the electric heater to ensure the safe operation of the electric heater. For liquid media, the end user must ensure that the heater can only work when it is completely immersed in the fluid. For heating in the tank, the liquid level needs to be controlled to ensure compliance. The outlet temperature measuring device is installed on the user's pipeline to monitor the exit temperature of the medium.