Max power of single heater up to 2000KW-3000KW, maximum voltage 690VAC
ATEX and IECExapproved. Exd, Exe, IIC Gb, T1-T6
Zone 1 & 2 applications
Ingress Protection IP66
High quality anti-corrosion/high temperature heating element materials:
Inconel 600
Incoloy 800/825/840
Hastelloy, Titanium
Stainless steel: 304, 321, 310S, 316L
NiCr 80/20 heating wires, single or double coils.
Design to ASME code and other International Standards.
Hair-pin element and sealing to tubesheet by means of Bite-Coupling or Direct Welding. When use with Bite-coupling, individual element can be replaced (offline).
Over-temperature protection on heating element/flange/terminal box by using PT100, Thermocouple and/or thermostat.
Flanged connection, ease of installation and maintenance.
Design for Life in cyclic or continuous operation.
Explosion Proof
Immersion heaters from WNH are used for applications such as the following:
lubricating oil heaters for turbines, compressors, pumps, refrigeration machines
heaters for heat transfer oil, heavy oil, fuels
container heaters for process water and emergency showers
heating of process gases
motor anticondesnation heaters
container and heating chamber heating
1.Are you factory?
Yes, we are factory, all customers are more than welcome to visit our factory .
2.What are the available product certifications?
We have certifications such as: ATEX, CE, CNEX. IS014001, OHSAS18001,SIRA, DCI. Etc
3.What other controls are needed for safe operation of the process heater?
The heater needs a safety device to ensure the safe operation of the heater.
Each heater is equipped with an internal temperature sensor, and the output signal must be connected to the control system to realize the over-temperature alarm of the electric heater to ensure the safe operation of the electric heater. For liquid media, the end user must ensure that the heater can only work when it is completely immersed in the fluid. For heating in the tank, the liquid level needs to be controlled to ensure compliance. The outlet temperature measuring device is installed on the user's pipeline to monitor the exit temperature of the medium.
4.What is a Flanged Immersion Heater?
A special heating element is connected to a flange. This is done with a hairpin bent element configuration. In some cases, tubular bugle elements are used. Tubing known as a thermowell is used to protect temperature probes, thermocouples and heating elements. Temperature readings are then transmitted to a control unit that powers the heat element on and off. For overload protection, a high limit sensor keeps the liquid from scorching or overheating and also serves to protect the flange immersion heater.
5.What should you do when buying your flange heaters
Before you purchase heaters for commercial applications, do not forget to keep these things in mind:
1. Voltage requirements – you may have three phase power or single phase in some applications.
2. Heat capacity
3. Housing
4. Sheath materials
5. Temperature controls
When you invest in flange process heaters you can greatly increase your efficiency. This means fewer problems and more profits, and that is a good strategy for keeping up with the competition